AOOS8000 Primary Cell Type Online Oxygen  Content Analyzer
AOOS8000 Primary Cell Type Online Oxygen  Content Analyzer
AOOS8000 Primary Cell Type Online Oxygen  Content Analyzer
+
  • AOOS8000 Primary Cell Type Online Oxygen  Content Analyzer
  • AOOS8000 Primary Cell Type Online Oxygen  Content Analyzer
  • AOOS8000 Primary Cell Type Online Oxygen  Content Analyzer

AOOS8000 Primary Cell Type Online Oxygen Content Analyzer

The product utilizes an instrument based on galvanic cell measurement, primarily designed for measuring the oxygen concentration in mixed gases, with a measurement range of 0% to 100% oxygen concentration. Under constant working pressure and temperature conditions, the voltage generated by the oxygen cell is proportional to the oxygen concentration. The output voltage of each oxygen cell remains essentially stable throughout its lifespan. When the measured oxygen concentration significantly deviates from the set value, the device will trigger an alarm. At this point, calibration can be performed. If the deviation persists, it typically indicates that the oxygen cell is depleted and requires replacement. The general service life of an oxygen cell is approximately 1 to 3 years.
  • Product description
  • Technical specifications
  • Product portfolio
    • AOOS8000 Primary Cell Type Online Oxygen Content Analyzer
    Measurement Principle  

    The product utilizes an instrument based on galvanic cell measurement, primarily designed for measuring the oxygen concentration in mixed gases, with a measurement range of 0% to 100% oxygen concentration. Under constant working pressure and temperature conditions, the voltage generated by the oxygen cell is proportional to the oxygen concentration. The output voltage of each oxygen cell remains essentially stable throughout its lifespan. When the measured oxygen concentration significantly deviates from the set value, the device will trigger an alarm. At this point, calibration can be performed. If the deviation persists, it typically indicates that the oxygen cell is depleted and requires replacement. The general service life of an oxygen cell is approximately 1 to 3 years.

     

     

    Main Features

     

    The instrument adopts a panel-mounted (160×80) structure;
    4-window high-brightness LED display;
    Conventional digital display meter operation menu;
    Optional sensing mounting base for easy sensor replacement;
    Imported sensors;
    Quick connector;
    Simultaneously display parameters such as measured values and alarm
    values;
    Panel-mounted snap-in structure for easy installation.
     
    ◆Application Scenarios
      The product is suitable for oxygen content measurement and over-limit alarm in large and medium-sized hyperbaric oxygen chambers in hospitals, as well as for industrial and mining
    enterprises, ship cabins, tunnels, coal mines, chemical equipment containers, and gas; internal combustion engine exhaust, thermoelectric devices, smelting, boilers, kilns, environmental
    protection monitoring, etc., oxygen generators, quality inspection, electrolytic hydrogen equipment, submarines, artificial satellites, civil air defense, aerospace; controlled atmosphere storage of
    grains, tobacco leaves, fruits, and vegetables, medical ventilators, anesthesia machines, and various other scenarios for oxygen content measurement, and can also be used for oxygen level control in respiration experiments on crops and animals.
     
     
  • ◆Technical Specifications
    HostPanel-mounted(160×80)
    Range0~30%
    Accuracy±0.2%
    Ambient temperature0~50℃
    Relative humidity≤90%RH
    Power supply90~265VAC、24±10%VDC
    Relay0.5A/240VAC,Resistive
    Transmitter output4~20mA,load impedance <600Ω
    Power consumption<5W
    Sensor mounting baseStainless steel,ABS
    Host displayLED,Four Windows
  • AOOS8000 Primary Cell Type Online Oxygen  Content Analyzer
    Instrument ModelAOOS8Primary Cell Type Online Oxygen  Content Analyzer
    Relay Output3Three Relay Outputs
    Measurement Input9User-specific Measurement Input
    Transmission Output0No Measurement Transmission Output
    50 to 10mA Measurement Transmission Output
    64 to 20mA Measurement Transmission Output
    70 to 5V Measurement Transmission Output
    81 to 5V Measurement Transmission Output
    9User-required Measurement Transmission Output
    External Shape StructureH8160×80 mm Horizontal Panel Meter
    V880×160 mm Vertical Panel Meter
    Power Distribution OutputNNo DC Power Distribution Output
    Power Supply ModeAAC 220V Power Supply Input
    DDC 24V Power Supply Input
    Communication Interface0No Isolated Communication Interface
    3Isolated RS232 Communication Interface
    8Isolated RS485 Communication Interface
    Sensor0No Oxygen Sensor
    1OS15 Oxygen Sensor
    2OS16 Sensor with Stainless Steel Base
    3OS17 Sensor with Plastic Base
    Model Selection ExampleAOOS8 - 3 - 9- 6-  H8-  N-  A-  0-  0

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

aotai02@fjautec.com      Mr. Zhang

aotai04@fjautec.com      Mr. Chen

Email:

autec@163.com


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd.,  All Rights Reserved.