AO5061 detection terminal voltage input isolated safety barrier (one in one out, one in two out)
- Product description
- Technical specifications
- Product portfolio
-
- AO5061 detection terminal voltage input isolated safety barrier (one in one out, one in two out)
◆ Performance Overview
Convert the voltage signal from the danger zone into a current/voltage signal through isolation and output it to the safe zone. The three terminal isolation of input, output, and power supply has the advantages of fast response, low power consumption, and good temperature characteristics.
-
◆ Technical parameters
Explosion proof mark: [Exia] IIC
Dangerous area allows input signal: voltage signal
Input impedance: ≥ 1MΩ
Signal frequency range: 0Hz~300Hz (customizable within the range of 0Hz~5kHz)
Can output signals to the safe zone:
Current: 0 (4) mA~20mA; 0mA~10mA;
Voltage: 0 (1) V to 5V; 0V~10V;
Load capacity
Current: 0 (4) mA~20mA: ≤ 300 Ω; 0mA~10mA: ≤ 600Ω
Voltage: 0 (1) V~5V: ≥ 1M Ω; 0V~10V: ≥ 2MΩ
Distribution output voltage: open circuit voltage ≤ 18V,
Voltage ≥ 14.5V at full load 20mA output
Output ripple:< 1mV
Isolation transmission accuracy: ± 0.2% F ∙ S (25 ℃± 2 ℃)
Temperature drift:< 30ppm/℃
Response time: ≤ 0.2ms
Stability time: ≤ 2ms
Dielectric strength: ≥ 2500V AC (between input/output/power supply, leakage current 1mA, test time 1min)
Insulation resistance: ≥ 100M Ω (between input/output/power supply)
Electromagnetic compatibility: EMC complies with IEC61000-4
Certification parameters of National Quality Supervision and Inspection Center for Instrumentation and Electrical Products (CQST): Um=250V AC/DC
9. Between terminals 11: Uo=21V,Io=125mA,Po=657mW
ⅡC ⅡB ⅡA
Co 0.13μF 0.89μF 3.34μF
Lo 1.59mH 4.77mH 12.72mH
10. Between terminals 11: Uo=13.7V,Io=3mA,Po=10.3mW
ⅡC ⅡB ⅡA
Co 0.553μF 3.50μF 12.6μF
Lo 1000mH 1000mH 1000mH
Power supply: DC 18-32V (typical value 24V DC)
Power consumption: 24V DC power supply, single output 0.4W
DC 24V power supply, dual output 0.6W
Message