    • AODDJ Conductivity Electrode

    I. Measurement Principle

    The instrument measures the conductivity of a medium by determining the AC impedance between the central electrode and the peripheral electrodes. Selecting an electrode with an appropriate cell constant, based on the expected conductivity range of the water sample, is crucial for accurate measurement. In particular, when measuring ultrapure water (conductivity < 1 μS/cm) or deionized water (conductivity < 3 μS/cm), it is essential to use electrodes with cell constants of 0.1 or 0.01, and, if necessary, employ a sealed measurement cell to ensure precision; otherwise, significant measurement errors may arise. The fundamental principle for electrode selection is as follows: choose an electrode with a suitable cell constant according to the anticipated conductivity range of the sample, referring to the table provided. A common mistake in electrode selection is using an electrode with a high cell constant to measure low-conductivity samples. For example, employing a 1.0‑cell‑constant electrode to measure water with a conductivity below 3 μS/cm will not yield accurate results. This is because low‑conductivity media exhibit very poor electrical conductivity; using a high‑cell‑constant electrode under such conditions produces an extremely weak and unstable signal, thereby substantially increasing measurement error.

    II. Main Features

    Stainless steel material;

    Built-in NTC temperature compensation;

    It can be processed into a variety of installation components.

    Optional flow cup;

    Simple structure, low maintenance requirements;

    High precision and fast response;

    Supports both threaded and flange mounting options.

    The equipment has a long service life.

    III. Application Scenarios

    This product is suitable for conductivity measurement in industrial applications such as environmental protection, wastewater treatment, and production processes in chemical and pharmaceutical plants.

    IV. Technical Parameters

    Project Parameter Details
    Range (Electrode Constant K)

    K=0.01, 0.01~20 μS/cm

     

    K=0.1, 0.1~200 μS/cm

     

    K=1.0, 1~2000 μS/cm

     

    K=10, 10 μS/cm ~ 20 mS/cm

     

    K=30, 30 μS/cm ~ 60 mS/cm

    Housing material 316L, 304, ABS, UPVC
    Process connection G3/4, 1-inch sanitary clamp, DN50 flange, custom-made
    Cable length Standard configuration: 3.3 meters
    Warm-tonifying NTC10K (0–99℃), NTC2.252K (0–70℃)

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

There is currently no relevant data available, please add it in the background!

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

 

Email:

autec@163.com


Copyright © 2025 Fujian AUTEC Factory Automation Equipment Co., Ltd.,  All Rights Reserved.