    • AOCON conductivity measuring instrument

    overview

     

      AOCON conductivity meters have strong environmental adaptability, LCD display, simple operation, and excellent testing performance, making them highly cost-effective. It can be widely used for continuous monitoring of conductivity values in solutions such as thermal power, chemical fertilizers, metallurgy, environmental protection, pharmaceuticals, biochemistry, food, and tap water.

     

    The AOCON conductivity meter simplifies its functions while ensuring performance, thus having a particularly strong price advantage. A secondary meter equipped with electrodes with a constant of 1.0 or 10 can measure the conductivity of general liquids; Equipped with electrodes of 0.1 or 0.01, it can accurately measure the conductivity of pure water or ultrapure water, especially suitable for online continuous monitoring of the conductivity of high-purity water such as boiler feedwater and steam condensate in power plants.

     

    Selection of electrodes

     

    The key to accurate measurement is to select an electrode with an appropriate constant based on the range of conductivity of the tested water sample. Especially for the measurement of pure water (<3 μ S/cm) and ultrapure water (<1 μ S/cm), 0.1 or 0.01 electrodes should be used, and if necessary, a closed measuring tank should be added to achieve accurate measurement, otherwise significant errors will occur.

     

    Doppler flow meter brings you professional service,the basic principle for selecting electrodes: Based on the range of conductivity of the measured water sample, refer to the table below to choose the electrode with the appropriate constant. A common mistake when selecting electrodes is to choose electrodes with high constants to measure low conductivity. If a 1.0 electrode is selected to measure water samples with<3 μ S/cm, it is impossible to obtain accurate values. Due to the poor conductivity of low conductivity media, using high constant electrodes for measurement will only result in weaker and more unstable electrical signals, which will significantly increase measurement errors.

     

    Measurement range of conductivity with various electrodes

     

    Measurement range, electrode constant, electrode model, remarks

     

    电导率测量仪表

     

    0.01~20 μ S/cm 0.01 AODDJ-0.01 should be added to a measuring slot for flow sealed measurement

     

    0.1~200μS/cm 0.1 AODDJ -0.10

     

    1~2000μS/cm 1.0 AODDJ -1.00

     

    10~6.0mS/cm 10 AODDJ -3.0

     

    Doppler FLOW METER brings you professional service,when measuring beyond the measurement range listed in the table above, the error will increase. When the conductivity value of the medium is greater than 100 μ S/cm, it is advisable to use a platinum black electrode with a constant of 1.0 or 10 for measurement to increase the effective area, significantly reduce the current density on the electrode surface, and effectively weaken the electrode polarization effect that is prone to occur when the medium is a concentrated solution.

     

    The electrode constant set in the instrument must be consistent with the constant marked on the electrode. If the electrode constant marked on the distribution pole is 0.102, then the electrode constant set in the instrument must be 0.102.

     

    2. If it is a flow-through installation, the outer diameter of the inlet and outlet pipes (three specifications: φ 8, φ 10, and φ 12), whether to use hoses or hard pipes, if not specified, will be equipped with a φ 10 hose connector.

     

    3. Inform the installation method of electrodes and secondary instruments.

     

    4. Please specify any other special requirements.

       

        Doppler flow meter

  • AOCON conductivity measuring instrument
    Instrument ModelAOCON6Conductivity Measuring Instrument
    Relay Output0Zero Reply Output
    1One Reply Output
    2Two Reply Output
    Input Sigal50.5mS/cm2000mS/cm
    60~100ms/cm
    Temperature Compensation0No(Sensor-integrated)
    4PT1000 Temperature Compensation Device
    Transmission Output0No Measurement Transmission Output
    50 to 10mA Measurement Transmission Output
    64 to 20mA Measurement Transmission Output
    70 to 5V Measurement Transmission Output
    81 to 5V Measurement Transmission Output
    9User-required Measurement Transmission Output
    ExternalShape StructureESP-A1 Cast Aluminum Enclosure
    Power Supply ModeDFour-wire 24VDC
    EFour-wire 12VDC
    Explosion-proof Type缺省Non-explosion-proof
    dExplosion-proof Type Exdll CT6
    Model Selection Example AOCON6 - 0 - 5 - 0 - 6 - E - D
       
    Note1The sensor's standard cable length is 5 meters

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

aotai02@fjautec.com      Mr. Zhang

aotai04@fjautec.com      Mr. Chen

Email:

autec@163.com


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd.,  All Rights Reserved.