• Product description
  • Technical specifications
  • Product portfolio
    • ADVRDV composite manhole flowmeter

    Measurement principle:

     

    The product uses a dual-mode sensor that combines radar Doppler and ultrasonic Doppler to sense water flow velocity, and then uses a combination of radar, static pressure, and conductivity sensors to sense water level changes, in order to calculate real-time flow rate of manholes.

     

    Doppler ultrasonic flowmeter brings you professional service,the design intention of this product is low operation and maintenance volume. In the scenario of manhole flow, it fully utilizes the advantage of non-contact flow measurement of radar, reduces the probability of sensor hanging, and supplements the flow velocity perception at high water levels through ultrasonic connection measurement. Multi sensing can enable products to complement each other's strengths and weaknesses, making them more suitable for working conditions.

     

    Main features:

     

    ▶  Dual mode flow velocity sensing (ultrasonic and radar waves), seamless docking (no blind spots);

     

    ▶  Pay attention to the boundary conditions of flow velocity: 0.2m/s~0.3m/s (non-contact radar flow velocity sensing);

     

    ▶  Multi mode perception of water level (radar, static pressure, and conductivity);

     

    ▶  Output parameters: comprehensive flow rate, comprehensive flow rate, comprehensive water level;

     

    ▶  Other parameters: single-mode flow rate, flow rate, water level, and sensor status;

     

    ▶  The top of the horizontal pipe is installed, and wellhead operations can be achieved through brackets;

     

    ▶  The host adopts an alloy plastic shell, which has anti-corrosion, waterproof, and impact resistance properties;

     

    ▶  Sealed with glue, not afraid of the impact of temperature changes on the seal;

     

    ▶  Supports RS485 upgrade and can achieve remote OTA with full host configuration;

     

    ▶  Installation at the top of horizontal pipelines can effectively prevent sensor hanging;

     

    ▶  The installation bracket can facilitate the fixation of sensors.

     

    Doppler ultrasonic flowmeter brings you professional service,application scenarios:

     

    Specialized sensor for measuring flow rate in manholes, suitable for remote sensing of flow velocity, water level, and flow rate in manholes.

     

     

  • Technical parameters:

    Flow velocity radarWater temperature rangepower consumption

    Flow rate range

    0.200~20.000m/s,Recommended operating conditions for speed measurement:>0.3m/s(Boundary flow velocity 0.2~0.3m/s)

    Flow velocity accuracy

    Ultrasonic: 1% ± 0.005m/s, Radar: 2% ± 0.01m/s

    Flow rate resolution

    0.001m/s

    Dead zone velocity

    Ultrasonic: 0~0.002m/s, Radar: 0~0.2m/s

    24G (operating frequency), CW, Antenna angle: 24 °× 12 °, radiated power EIRP: 20dBm, antenna gain: 18.5dB

     

    ultrasonic sensor

    3 beams, 2MHz, 45 ° angle

    Water level range

    0~10m(Radar+Static Pressure+Conductivity Composite Sensing)

    Water level accuracy

    0.2%FS±0.001m

    Water level resolution

    0.001m

    Water level radar

    80G range: 0.15-40 meters (affected by RCS), FMCW, Antenna angle: 14 °× 10 °

    0-60℃

     

    Water temperature accuracy

    0.5℃

    Water temperature resolution

    0.1℃

    power supply

    8-15VDC,Typical values:12VDC

    output

    RS485.MODBUS.RTU

    Output damping

    can be set

    12VDC/150mA

     

    response time

    10s

     


     

  • ADVRDV composite manhole flowmeter
    Instrument ModelADVRDVComposite Manhole Flowmeter
    Flow Velocity and Water Level0Flow Velocity: 0.05m/s~20m/s            Water Level: 0~10m
    Process Connection Accessories0Standard L-shaped 304 stainless steel bracket
    Power Supply/CommunicationE12VDC(RS485)
    Cable LengthA10 meters (standard configuration)
    B20 meters
    Ccustom length (*Note 3)
    Breather Valve Assembly0Without manhole breather valve assembly (*Note 1)
    1With manhole breather valve assembly + cable lead-out (*Note 2)
    2With manhole breather valve assembly + aviation connector (*Note 4)
    Model Selection ExamplesADVRDV - 0 - 0 - E -  A - 0
       
    *Note1Except when the customer does not require the manhole breather valve, this option shall also be selected when the ADVRDV is used in conjunction with the AOWXM stainless steel barrel;
    *Note2When using this product in a manhole, it is recommended to select the manhole breather valve assembly; however, the cable cannot be threaded through a pipe in this case, so please note this when selecting.
    *Note3The length of the cable led out from the breather valve is 0.5 meters, and self-extending of the cable is not supported;

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

aotai02@fjautec.com      Mr. Zhang

aotai04@fjautec.com      Mr. Chen

Email:

autec@163.com


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd.,  All Rights Reserved.