AOXY6000 Fluorescence Dissolved Oxygen Analyzer
+
  • AOXY6000 Fluorescence Dissolved Oxygen Analyzer

AOXY6000 Fluorescence Dissolved Oxygen Analyzer

This product uses fluorescence method to measure dissolved oxygen. The top of the sensor is covered with a layer of fluorescent substance. When the blue light emitted by the sensor shines on the fluorescent substance, it is excited and emits red light. Due to the quenching effect of oxygen molecules, the time and intensity of the excited red light are directly proportional to the concentration of oxygen molecules. The concentration of dissolved oxygen in water can be calculated.
  • Product description
  • Technical specifications
  • Product portfolio
    • AOXY6000 Fluorescence Dissolved Oxygen Analyzer

    AOXY6000 Fluorescence Dissolved Oxygen Analyzer

     

    This product uses fluorescence method to measure dissolved oxygen. The top of the sensor is covered with a layer of fluorescent substance. When the blue light emitted by the sensor shines on the fluorescent substance, it is excited and emits red light. Due to the quenching effect of oxygen molecules, the time and intensity of the excited red light are directly proportional to the concentration of oxygen molecules. The concentration of dissolved oxygen in water can be calculated.


          Doppler flow meter

    Doppler flow meter brings you professional service,the sensor adopts a new type of oxygen sensitive membrane with built-in NTC temperature compensation function, and the measurement results have good repeatability and stability;

     

    There will be no oxygen consumption during measurement, and there are no requirements for flow rate and agitation;

     

    Breakthrough fluorescence technology without membranes or electrolytes, requiring minimal maintenance;

     

    Built in self diagnosis function to ensure accurate data;

     

    Factory calibration, no calibration required for one year, can be calibrated on-site;

     

    Digital sensors with strong anti-interference ability and long transmission distance;

     

    Standard digital signal output, which can be integrated and networked with other devices without a transmitter;

     

    The on-site installation of sensors is convenient and fast, achieving plug and play functionality.

     

    Range: 0-20mg/L or 0-200% saturation; Temperature: 0-45 degrees Celsius

     

    Accuracy: 3%

     

    Pressure less than: 0.3MPa

     

    Material: 316L

     

    Size: Diameter 49.5, Length 251.5

     

    IP68

     

    Standard: 10 meter cable

  •  

    AOXY6000 Fluorescence Dissolved Oxygen Analyzer
    Instrument ModelAOXY5000On-line Dissolved Oxygen Monitor
    Relay Output0Zero Relay Outputs
    1One Relay Output
    2Two Relay Output
    3Three Relay Output
    4Four Relay Output
    Input Signal1ppm Dissolved Oxygen Electrode
    2ppb Dissolved Oxygen Electrode
    3Fluorescent Dissolved Oxygen Electrode (*Note 1)
    Temperature Compensation0No Temperature Compensation Device (for Fluorescent Dissolved Oxygen Electrode only)
    1Temperature Compensation Device NTC2.252K (for Polarographic Dissolved Oxygen Electrode only)
    2Temperature Compensation Device NTC10K (for Polarographic Dissolved Oxygen Electrode only)
    Transmission Output0No Measurement Transmission Output
    50 to 10mA Measurement Transmission Output
    64 to 20mA Measurement Transmission Output
    70 to 5V Measurement Transmission Output
    81 to 5V Measurement Transmission Output
    9User-required Measurement Transmission Output
    External Shape StructureS996×96 mm Square Panel Meter
    ESP-A1 Aluminum Die-Cast Housing
    F215mm × 165mm × 70mm (Wall-Mounted Type)
    Power Distribution OutputNNo DC Power Distribution Output (Only optional for Type E Fluorescent Dissolved Electrode)
    P24V/50mA DC Power Distribution Output
    Power Supply ModeAAC 220V Power Supply Input
    DDC 24V Power Supply Input
    Communication Interface0No Isolated Communication Interface (Only optional for Type S9 and Type E Fluorescent Dissolved Electrodes)
    8RS485 Isolated Communication Interface
    Sensor0Without Sensor
    1With Sensor
    Explosion-proof Type/Non-Explosion-Proof
    dExplosion-Proof Type Ex d II CT6
    Model Selection ExampleAOXY - 0 - 3 - 0 - 6 - E - N - A - 0 - 1 - d
    Note1Type S9 and Type E fluorescent dissolved electrodes will occupy the 485 communication interface; therefore, the device cannot support the 485 communication function.

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

aotai02@fjautec.com      Mr. Zhang

aotai04@fjautec.com      Mr. Chen

Email:

autec@163.com


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd.,  All Rights Reserved.