Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
+
  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter

Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter

Customization:Available Accuracy:±0.2-0.5% Main Application:Water
  • Product description
  • Technical specifications
  • Product portfolio
    • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter

     

    Product Description

    Electromagnetic flowmeter is composed of two parts: sensor and converter. It works based on Faraday's law of electromagnetic induction and is used to measure conductive liquids or two-phase media. Its conductivity is generally required to be greater than 5 μ S/cm (the original conductivity of tap water is about 100-500 μ S/cm). It can be used to measure various acid, alkali, salt solutions, pulp, slurry and other media, but the media cannot contain a lot of ferromagnetic substances and a large number of bubbles.

    Electromagnetic flowmeter is a major flow meter widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management and water conservancy construction for flow measurement.

    The measurement system of the electromagnetic flowmeter sensor is based on Faraday's law of electromagnetic induction. A pair of detection electrodes are installed on the pipe wall perpendicular to the axis of the measuring tube and the magnetic field lines. When the conductive liquid moves along the axis of the measuring tube, it cuts the magnetic field lines and generates an induced potential. This induced potential is detected by two electrodes on the measuring tube, with a value of:

    E=KBVD

    Among them: E induced potential;

    K instrument constant;

    B magnetic induction intensity;

    Measure the average flow velocity within the cross-section of the V measuring tube;

    D Measure the inner diameter of the tube;

    When measuring flow rate, the fluid flows through a magnetic field perpendicular to the flow direction, and the flow of conductive liquid induces an electric potential proportional to the average flow velocity. Therefore, it is required that the measured flowing liquid has a conductivity higher than the minimum limit. The induced voltage signal is detected through two electrodes. And it is transmitted to the converter through cables, and after signal processing and related operations, the accumulated flow rate and instantaneous flow rate are displayed on the converter's display screen.

    Instrument features

    1. There are no obstructions or moving parts inside the measuring tube, so it will not cause additional energy loss or blockage, resulting in significant energy-saving effects. It is particularly suitable for measuring liquid-solid two-phase flows such as sewage, mud, slurry, coal water slurry, pulp, etc.

    2. Only the lining and electrode are in contact with the measured medium. As long as the lining and electrode materials are selected reasonably, good corrosion resistance and wear resistance can be achieved. Therefore, various chemical solutions such as strong acids and bases can be measured.

    3. Low installation requirements. The front straight pipe section is only 5D, while the rear straight pipe section is 2D (D is the inner diameter of the selected instrument).

    4. The measurement accuracy is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity, and can measure flow in both forward and reverse directions, which provides a good means for accurately measuring flow.

    5. The power consumption of the instrument is low, less than 5VA.

    6. The converter has good interchangeability and can achieve measurement accuracy without the need for re calibration of the real current. Due to its various advantages, electromagnetic flow meters are becoming increasingly widely used in various industries and have become the preferred instrument for liquid flow measurement.

     

    Product Parameters

    Please read this information carefully before placing an order to understand the model and coding regulations of this product, and determine the model specifications as needed.

    If necessary, please fill out the electromagnetic flowmeter selection operating condition table.

    Technical parameters of AO-ATF-A/B (integrated/split type) universal electromagnetic flowmeter

    1. Caliber DN10~DN2000

    2. Electrode material 316 Hb,Hc,Ti,Ta,Pt

    3. Inner lining materials PTFE, PFA, F46, chloroprene rubber, polyurethane

    4. Dielectric conductive liquid (including solid-liquid two-phase)

    5. Measurement errors of ± 0.3%, ± 0.5%, ± 1.0% flow rate (by caliber)

    6. Dielectric conductivity>5 μ S/cm (water>20 μ S/cm)

    7. Flow velocity range of 0.5-10m/s (flow unit can be selected)

    8. Connect the flange according to the national standard GB9115 or according to user requirements

    9. Integrated medium temperature -10 ºC~+60 ºC, split type -10 ºC~+150 ºC

    10. Rated pressure 0.6MPa~4.0MPa (by caliber)

    11. Protection levels IP65, IP67, IP68 (split type)

    12. Converter with integrated or split design

    13. Output signal 4-20mA output, frequency/pulse output

    14. Communication RS485, RS232

    15. Application of acid, alkali, water supply and drainage, food, pulp, slurry, etc

    16. Display flow rate, flow rate, percentage, cumulative flow rate, fault alarm, etc

    17. Power supply 220VAC, 24VDC

    18. Installation form: integrated or split type

     

    Technical parameters of AO-ATF-C/D (integrated/split) clamping electromagnetic flowmeter

    1. Caliber DN10~DN200

    2. Electrode material 316 Hb,Hc,Ti,Ta,Pt

    3. Lining material PFA, F46

    4. Dielectric conductive liquid (including solid-liquid two-phase)

    5. Measurement errors of ± 0.3%, ± 0.5%, ± 1.0%

    6. Dielectric conductivity>5 μ S/cm (water>20 μ S/cm)

    7. Flow range 0.5-10m/s

    8. Integrated medium temperature -10 ºC~+60 ºC, split type -10 ºC~+150 ºC

    9. Rated pressure 1.6MPa~4.0MPa (by caliber)

    10. Protection levels IP65, IP67, IP68 (split)

    11. Output signal 4-20mA output, frequency/pulse output

    12. Communication RS485, RS232

    13. Application of acid, alkali, water supply and drainage, food, pulp, etc

    14. Display flow rate, flow rate, percentage, cumulative flow rate, fault alarm, etc

    15. Power supply 220VAC, 24VDC

    16. Installation form: integrated or split type

  • Basic Info.

    Model NO.AO-ATFSizeDN10-500
    SensorTube/FlangeApplicationIndustrial Production
    TypeElectromagnetic Flow MeterMeasuring MediaLiquid
    Measuring PrincipleElectrical PrinciplesMeasurement ObjectClosed Pipeline
    CertificationJIS, DIN, ANS, GB, CE,ISOPower Supply220V/24V/Battery
    Signal Output4-20mA;PulseSupply Voltage110/220VAC;24VDC+10%
    Compact TypeIP65Body MaterialCarbon Steel
    Nominal Pressure1.0~4.0MPaTransport PackageCartons and Wooden Box
    SpecificationDN10-500TrademarkAUTEC
    OriginFujin ChinaHS Code9026100000
    Production Capacity2000  

     

  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
    Instrument ModelAO-ATF-AElectromagnetic Mag Flowmeter
    Caliber( )Caliber from DN6 to DN65
    Body MaterialA304SS
    B316LSS
    Electrode1316LSS
    9OTHER
    Lining MaterialAPolyetheretherketone (PEEK)
    Connection Method1Threaded Connection Type (British Standard G Thread)
    2Clamp Connection Type (ISO2852 Clamp)
    3Flange Connection Type (HG/T20592)
    Working Pressure1-0. 1MPa~6.3MPa
    Protection ClassAIP67
    Output Method0No Output
    14~20mA
    Communication Method0No 
    1RS485 (MODBUS-RTU Communication Protocol)
    Power Supply MethodW18~36VDC
    Accuracy50.5Level
    Maximum Flow Rate(  )Indicate the maximum flow rate in parentheses, with the unit m³/h
    Model Selection ExamplesAO-ATF-F-(DN25)-A-1-A-1-1-A-0-1-W-5-8

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

aotai02@fjautec.com      Mr. Zhang

aotai04@fjautec.com      Mr. Chen

Email:

autec@163.com


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd.,  All Rights Reserved.