    Product scope of application

     

    Electromagnetic flowmeter is composed of two parts: sensor and converter. It works based on Faraday's law of electromagnetic induction and is used to measure conductive liquids or two-phase media. Its conductivity is generally required to be greater than 5 μ S/cm (the original conductivity of tap water is about 100-500 μ S/cm). It can be used to measure various acid, alkali, salt solutions, pulp, slurry and other media, but the media cannot contain a lot of ferromagnetic substances and a large number of bubbles.

     

    electromagnetic Flowmeter is a major FLOW METER widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management and water conservancy construction for flow measurement.

     

    electromagnetic Flowmeter    

        electromagnetic Flowmeter


     

     

    The measurement system of the electromagnetic flowmeter sensor is based on Faraday's law of electromagnetic induction. A pair of detection electrodes are installed on the pipe wall perpendicular to the axis of the measuring tube and the magnetic field lines. When the conductive liquid moves along the axis of the measuring tube, it cuts the magnetic field lines and generates an induced potential. This induced potential is detected by two electrodes on the measuring tube, with a value of:

     

        

     

    E=KBVD

     

    Among them: E induced potential;

     

    K instrument constant;

     

    B magnetic induction intensity;

     

    Measure the average flow velocity within the cross-section of the V measuring tube;

     

    D Measure the inner diameter of the tube;

     

    When measuring flow rate, the fluid flows through a magnetic field perpendicular to the flow direction, and the flow of conductive liquid induces an electric potential proportional to the average flow velocity. Therefore, it is required that the measured flowing liquid has a conductivity higher than the minimum limit. The induced voltage signal is detected through two electrodes. And it is transmitted to the converter through cables, and after signal processing and related operations, the accumulated flow rate and instantaneous flow rate are displayed on the converter's display screen.

     

    Instrument features

     

    1. There are no obstructions or moving parts inside the measuring tube, so it will not cause additional energy loss or blockage, resulting in significant energy-saving effects. It is particularly suitable for measuring liquid-solid two-phase flows such as sewage, mud, slurry, coal water slurry, pulp, etc.

     

    2. Only the lining and electrode are in contact with the measured medium. As long as the lining and electrode materials are selected reasonably, good corrosion resistance and wear resistance can be achieved. Therefore, various chemical solutions such as strong acids and bases can be measured.

     

    3. Low installation requirements. The front straight pipe section is only 5D, while the rear straight pipe section is 2D (D is the inner diameter of the selected instrument).

     

    4. The measurement accuracy is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity, and can measure flow in both forward and reverse directions, which provides a good means for accurately measuring flow.

     

    5. The power consumption of the instrument is low, less than 5VA.

     

    6. The converter has good interchangeability and can achieve measurement accuracy without the need for re calibration of the real current. Due to its various advantages, electromagnetic flow meters are becoming increasingly widely used in various industries and have become the preferred instrument for liquid flow measurement.

     

    Ordering Instructions

     

    Please read this information carefully before placing an order to understand the model and coding regulations of this product, and determine the model specifications as needed.

     

    If necessary, please fill out the electromagnetic flowmeter selection operating condition table.

     

    Technical parameters of AO-ATF-A/B (integrated/split type) universal electromagnetic flowmeter

     

    1. Caliber DN10~DN2000

     

    2. Electrode material 316 Hb、Hc、Ti、Ta、Pt

     

    3. Inner lining materials PTFE, PFA, F46, chloroprene rubber, polyurethane

     

    4. Dielectric conductive liquid (including solid-liquid two-phase)

     

    5. Measurement errors of ± 0.3%, ± 0.5%, ± 1.0% flow rate (by caliber)

     

    6. Dielectric conductivity>5 μ S/cm (water>20 μ S/cm)

     

    7. Flow velocity range of 0.5-10m/s (flow unit can be selected)

     

    8. Connect the flange according to the national standard GB9115 or according to user requirements

     

    9. Integrated medium temperature -10 ℃~+60 ℃, split type -10 ℃~+150 ℃

     

    10. Rated pressure 0.6MPa~4.0MPa (by caliber)

     

    11. Protection levels IP65, IP67, IP68 (split type)

     

    12. Converter with integrated or split design

     

    13. Output signal 4-20mA output, frequency/pulse output

     

    14. Communication RS485, RS232

     

    15. Application of acid, alkali, water supply and drainage, food, pulp, slurry, etc

     

    16. Display flow rate, flow rate, percentage, cumulative flow rate, fault alarm, etc

     

    17. Power supply 220VAC, 24VDC

     

    18. Installation form: integrated or split type

     

    Technical parameters of AO-ATF-C/D (integrated/split) clamping electromagnetic flowmeter

     

    1. Caliber DN10~DN200

     

    2. Electrode material 316 Hb、Hc、Ti、Ta、Pt

     

    3. Lining material PFA, F46

     

    4. Dielectric conductive liquid (including solid-liquid two-phase)

     

    5. Measurement errors of ± 0.3%, ± 0.5%, ± 1.0%

     

    6. Dielectric conductivity>5 μ S/cm (water>20 μ S/cm)

     

    7. Flow range 0.5-10m/s

     

    8. Integrated medium temperature -10 ℃~+60 ℃, split type -10 ℃~+150 ℃

     

    9. Rated pressure 1.6MPa~4.0MPa (by caliber)

     

    10. Protection levels IP65, IP67, IP68 (split)

     

    11. Output signal 4-20mA output, frequency/pulse output

     

    12. Communication RS485, RS232

     

    13. Application of acid, alkali, water supply and drainage, food, pulp, etc

     

    14. Display flow rate, flow rate, percentage, cumulative flow rate, fault alarm, etc

     

    15. Power supply 220VAC, 24VDC

     

    16. Installation form: integrated or split type

     

     

  • Technical parameters of intelligent converter

     

    conductivity

    >5μS/cm

    flow rate range

    0.5~ 10m/s

    current output

    Bidirectional two-way, fully isolated, 0-10mA (load resistance 0-1.2K Ω),


     

    4-20mA (load resistance 0-600 Ω)

     

    Frequency output

    The upper limit is set within 0-3KHz. Open collector output of transistor with photoelectric isolation

    pulse output

    The upper limit can reach 5000cp/s, and the pulse equivalent is 0.0001-10m3/cp. The pulse width is between 10ms and 2.5s. Transistor collector open circuit alarm output with photoelectric isolation, collector open circuit alarm output with positive and negative flow state. The external power supply for the above three outputs is not greater than 35V. When conducting, the collector current is 250mA

    communication interface

    RS485,RS232

    quarantine

    The insulation voltage between the analog output, pulse output, alarm output and the ground shall not be less than 500V

    power supply

    220VAC,24VDC

    power

    ≤20W

    ambient temperature

    -10~+ 60℃

    display

    High definition backlit LCD display, instantaneous, cumulative (forward cumulative, reverse cumulative, and differential cumulative)

    power-off protection

    Accumulated value data saved for more than 10 years

    Shell protection

    IP65,IP67,IP68(split type)


     

  • Ao-Atf DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
    Instrument ModelAO-ATF-AElectromagnetic Mag Flowmeter
    Caliber( )Caliber from DN6 to DN65
    Body MaterialA304SS
    B316LSS
    Electrode1316LSS
    9OTHER
    Lining MaterialAPolyetheretherketone (PEEK)
    Connection Method1Threaded Connection Type (British Standard G Thread)
    2Clamp Connection Type (ISO2852 Clamp)
    3Flange Connection Type (HG/T20592)
    Working Pressure1-0. 1MPa~6.3MPa
    Protection ClassAIP67
    Output Method0No Output
    14~20mA
    Communication Method0No 
    1RS485 (MODBUS-RTU Communication Protocol)
    Power Supply MethodW18~36VDC
    Accuracy50.5Level
    Maximum Flow Rate(  )Indicate the maximum flow rate in parentheses, with the unit m³/h
    Model Selection ExamplesAO-ATF-F-(DN25)-A-1-A-1-1-A-0-1-W-5-8

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

aotai02@fjautec.com      Mr. Zhang

aotai04@fjautec.com      Mr. Chen

Email:

autec@163.com


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd.,  All Rights Reserved.