    • AO920W ceramic capacitor type input level transmitter

    measuring principle

    The product uses ceramic substrates and diaphragms coated with metal as electrodes,maintaining a controllable gap between the two ceramic components to form a capacitor.By applying pressure,the gap between the substrate and    diaphragm changes,altering the capacitance.This change is then processed by a circuit to generate a pressure-

    related signal output.This dry pressure measurement technology,which does not use an intermediary liquid,fully leverages the technical advantages of ceramic sensors,such as their ability to withstand overloads and shocks,    excellent stability,and high measurement accuracy.

     

    main features

     The sensor is a "E+H"dry ceramic sensor with compensation;

       Excellent  overvoltage  performance,can  reach  200  times  of  the range;

    Without    intermediary     liquid,the    sensor     can    obtain     good measurement accuracy and is less affected by temperature;

    Waterproof,dustproof,shockproof,explosion-proof,corrosion- resistant;

    Liquid     contact      material:membrane(alumina      ceramic),connection: 316L,seal:fluororubber;

      Explosion-proof:intrinsically  safe  (need  to  be  used  with  input type safety  barrier),explosion-proof;high  precision,good  stability;

    The  seismic  performance  is  good  and  there  are  no  mechanical  moving parts;

    It has PV reset function;

    The   menu    is   rich   and    can   set    various   parameters;

     Supports HART communication protocol;

     Stable backlight display,make reading the meter easier;

    Shell    material:aluminum(conventional),stainless     steel;

     

    application scenarios

    It is suitable for use in the industrial field of liquid level measurement.According to the temperature,pressure,

    corrosiveness,explosion-proof requirements,safety  requirements,measurement  range  and  other working  conditions  of the medium,each type of products are selected.

     

     

  • technical parameter

    accuracy±0.1%、±0.2%、±0.5%
    level0~20m intervals,others
    mediumliquid
    temperature-40.0~85℃
    protectBetter than IP65
    stabilityBetter than ±0.1%FS/1 year
    Vibration effectsAt 20~200Hz in any direction,the variation is less than±0.02%BFSL
    shock effectWhen the 100G impact is 11ms in any direction,the change is less than±
    0.02%BFSL
    Load impactAs long as the terminal voltage of the transmitter is greater than 12VDC
    Production
    options
    No oil,no water,no oil,no fat
    explosion-proofExiallCT6 Intrinsically safe,ExdIICT6 Flameproof
    Power Supply
    Voltage
    12~36VDC,two-wire system
    signalTwo-wire 4~20mA,HART
  • AO920W ceramic capacitor type input level transmitter
    Instrument ModelAO920Wceramic capacitor type input level transmitter
    Measurement RangeF2Split-Type Anti-Corrosion Cable-Mounted (Note 1)
    DFlange Direct-Mount Type (Note 2)
    Measurement Range (Note: Specify the factory-set range when ordering; if not specified, it will be delivered with the maximum rated range)A0~1mH2O 
    B0~2mH2O 
    C0~5mH2O 
    D0~10mH2O
    E0~20mH2O
    F0~50mH2O
    G0~100mH2O
    H0~200mH2O
    Output Signal8RS485-ModBus RTU Communication
    E4~20mADC
    SIntelligent HART Fieldbus Protocol Interface
    Basic Error20.10%
    30.20%
    40.50%(note3)
    9other
    OptionsM33 1/2-Digit LCD Digital Display Head
    B3Pipe-Mounted Flat Bracket
    B4L-Shaped Mounting Bracket (316 Material) 
    EMounting Flange Available (Note: Size)
    iIntrinsically Safe Type Exia IIC T6
    dExplosion-Proof Type Exd IIC T6
    LLightning Protection
    Cable LengthLMUnit: Meter (m)
    Selection ExampleAO920W - F2 - C - S - 3 -M3d - 005
       
    Note1The process connection thread of the split-type level transmitter is M66*2, which is compatible with flanges above DN65.
    Note2The process connection method of the flange direct-mount level transmitter is DN50-1.0 flange (default). For special orders, please specify
    Note3Models with 0.1% and 0.2% accuracy come standard with an LCD digital display head.;
    Note4This product must NOT be used with media containing acetic acid, ammonia, etc.;
    Note5When equipped with RS485-ModBus RTU communication output, the accuracy is 0.5% by default.

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

aotai02@fjautec.com      Mr. Zhang

aotai04@fjautec.com      Mr. Chen

Email:

autec@163.com


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd.,  All Rights Reserved.