AO5019NPN detection terminal proximity switch input isolated safety barrier collector (two in two out)
+
  • AO5019NPN detection terminal proximity switch input isolated safety barrier collector (two in two out)

AO5019NPN detection terminal proximity switch input isolated safety barrier collector (two in two out)

The NAMUR proximity switch signal in the hazardous area is isolated and converted to output to the safe area. The output mode is open circuit output with two collectors, and can also be selected for reverse phase.
  • Product description
  • Technical specifications
  • Product portfolio
    • AO5019NPN detection terminal proximity switch input isolated safety barrier collector (two in two out)

    Performance Overview

    The NAMUR proximity switch signal in the hazardous area is isolated and converted to output to the safe area. The output mode is open circuit output with two collectors, and can also be selected for reverse phase.

    The input terminal, output terminal, and power supply terminal are isolated from each other, and have the function of detecting line faults.

     

     

     

    Usage environment

    Working environment temperature: -20 ℃ to+60 ℃
    Allowable relative humidity at work: 10% RH to 90% RH (40 ℃)
    Allowable atmospheric pressure during work: 80kPa~106kPa
    Allowable ambient temperature during storage and transportation: -40 ℃ to+80 ℃

  • Technical Specifications

    Explosion proof grade: [Exia] IIC

    Dangerous area allows input signal: NAMUR proximity switch

    Active signal trigger point: When the input signal is greater than 2.1m Α, it is indicated as "ON"

    When the input signal is less than 1.2m Α, it is indicated as "OFF"

    Short circuit current: about 8m Α Open circuit voltage: 8V

    Line fault detection function (LFD): If the input current is less than 50 μ A, it is judged as input disconnection

    Input current>6mA, judged as input short circuit

    Output signal to safe zone: open collector

    Current output: ≤ 40mA

    External high input voltage: 40V DC

    Short circuit current:<100mA

    Input and output are reversed control settings: K1 and K3 are set to the ON side, and the input and output of the corresponding channel are reversed.

    K1 and K3 are set as side 1, and the input and output of the corresponding channels on side 3 are in phase.
    K2 and K4 are set to the ON side without LFD function.
    K2 and K4 are set to 2 sides, with LFD indicator function on 4 sides.
    Switching frequency: ≤ 5kHz
    Dielectric strength: ≥ 2500V AC (between input/output/power supply, leakage current 1mA, testing time 1min)
    Insulation resistance: ≥ 100M Ω (between input/output/power supply)
    Electromagnetic compatibility: EMC complies with IEC61000-4
    Certification parameters of National Quality Supervision and Inspection Center for Instrumentation and Electrical Products (CQST): Um=250V AC/DC
    9. Between 10 terminals, between 11 and 12 terminals: Uo=10.5V, Io=13mA, Po=34mW
    ⅡC           ⅡB           ⅡA
    Co        1.6μF         11.7μF       52.5μF
    Lo        147mH         441mH        1000mH
    Power supply: DC 18V~32V (typical value 24V DC)
    Power consumption: DC 24V power supply, two collector open circuit outputs 1.0W

Message

If you have any needs, please feel free to contact us at any time.

Submit Now

Related Products

message

HOW CAN WE HELP ?

Get In Touch With Us!

%{tishi_zhanwei}%

Contact Us

Address:

No.36, Longhui Road, Wujin National Hi-Tech Industrial Development Zone, Jiangsu Province, China

Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, Fuzhou City

Tel:

+86-13055728858

Email:

aotai03@fjautec.com      Mr. Zhou

aotai01@fjautec.com       Mr. Liao

aotai02@fjautec.com      Mr. Zhang

aotai04@fjautec.com      Mr. Chen

Email:

autec@163.com


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd.,  All Rights Reserved.